hl7:observation
|
|
1 … 1 |
M |
|
(XeH ion) |
@classCode
|
cs |
1 … 1 |
F |
OBS |
@moodCode
|
cs |
1 … 1 |
F |
EVN |
hl7:templateId
|
II |
1 … 1 |
M |
|
(XeH ion) |
@root
|
uid |
1 … 1 |
F |
2.16.840.1.113883.2.51.10.56 |
hl7:templateId
|
II |
1 … 1 |
M |
|
(XeH ion) |
@root
|
uid |
1 … 1 |
F |
1.3.6.1.4.1.19376.1.3.1.6 |
hl7:id
|
II |
0 … 1 |
|
A Laboratory Observation identifier MAY be present. |
(XeH ion) |
hl7:code
|
CD |
1 … 1 |
R |
Unique test code in an international standard (LOINC or SNOMED CT) or a national standard
(e.g. JC10 in Japan)
|
(XeH ion) |
hl7:statusCode
|
CS |
1 … 1 |
M |
Formal status according to IHE XD-LAB profile: ‘completed’ when the result is present ‘aborted’ if the test could not be performed
|
(XeH ion) |
|
CONF |
@code shall be "completed" |
or |
@code shall be "aborted" |
|
xeh:observationStatus
|
CO |
1 … 1 |
M |
Status of Laboratory Test in the context of the workflow / business process, such
as preliminary, final, corrected, ...
The value must not contradict the value set in hl7:statusCode
|
(XeH ion) |
|
CONF |
|
hl7:effectiveTime
|
IVL_TS |
0 … 1 |
R |
Physiologically relevant time |
(XeH ion) |
hl7:value
|
ANY |
0 … 1 |
R |
The result obtained for this test using the appropriate data type. Numeric results
use data type PQ, which includes the unit. The result is absent in case of ‘obsolete’
or ‘aborted’ observation.
|
(XeH ion) |
hl7:interpretationCode
|
CE |
0 … 1 |
R |
One or more codes interpreting the result, expressed with ObservationInterpretation
vocabulary (e.g. H = high, L = low) In case of a antimicrobial susceptibility test in microbiology, the vocabulary domain
is ObservationInterpretationSusceptibility: S = susceptible, R = resistant, I = intermediate,
VS = very susceptible, MS = moderately
susceptible
|
(XeH ion) |
hl7:methodCode
|
CE |
0 … 1 |
R |
method used for this observation expressed with ObservationMethod vocabulary (CWE) |
(XeH ion) |
Choice |
0 … 1 |
|
Elements to choose from:
|
hl7:subject
|
|
|
NP |
subject in case of a non-human subject Contains 1.3.6.1.4.1.19376.1.3.3.1.2.1 Non-Human Subject (DYNAMIC)
|
(XeH ion) |
@typeCode
|
cs |
0 … 1 |
F |
SBJ |
hl7:subject
|
|
0 … 1 |
|
subject in case of a non-human subject Contains 1.3.6.1.4.1.19376.1.3.3.1.3.1 Human Patient with Non-Human Subject (DYNAMIC)
|
(XeH ion) |
@typeCode
|
cs |
0 … 1 |
F |
SBJ |
hl7:performer
|
|
0 … * |
|
performer participation. Performer to supersede those recorded at higher level. Contains 1.3.6.1.4.1.19376.1.3.3.1.7 Laboratory Performer (DYNAMIC)
|
(XeH ion) |
@typeCode
|
cs |
0 … 1 |
F |
PRF |
hl7:author
|
|
0 … * |
R |
author participation used to supersede the authors of higher level. Contains 1.3.6.1.4.1.19376.1.3.10.9.17 Author with Name, Addr, Telecom (DYNAMIC)
|
(XeH ion) |
@typeCode
|
cs |
0 … 1 |
F |
AUT |
hl7:participant
|
|
0 … 1 |
|
Other participants "AUTHEN", "RESP", and "DEV".
- AUTHEN: The verifier of the battery organizer. In the case where a laboratory report
has multiple verifiers. Each verifier is attached to the subset of batteries/observations
he or she verified, by the means of a <participant> element.
|
(XeH ion) |
where [@typeCode='AUTHEN'] |
|
@typeCode
|
cs |
1 … 1 |
F |
AUTHEN |
hl7:participant
|
|
0 … 1 |
|
Other participants "AUTHEN", "RESP", and "DEV".
- RESP: The person responsible for the provision of the battery. In the case where this
battery is subcontracted to an external laboratory, this external laboratory (with
its address and telcom) and the actual performer is represented by a <performer> element,
whereas the Director of this subcontractor laboratory is carried by the <participant>
element
being attached to the same level as the <performer> element.
|
(XeH ion) |
where [@typeCode='RESP'] |
|
@typeCode
|
cs |
1 … 1 |
F |
RESP |
hl7:participant
|
|
0 … 1 |
|
Other participants "AUTHEN", "RESP", and "DEV".
- DEV: A device or equipment, which was used to produce this battery of results (e.g.
an analyzer).
|
(XeH ion) |
where [@typeCode='DEV'] |
|
@typeCode
|
cs |
1 … 1 |
F |
DEV |
hl7:entryRelationship
|
|
0 … * |
R |
Comment on this Observation Contains 1.3.6.1.4.1.19376.1.5.3.1.4.2 IHE Comment Entry (DYNAMIC)
|
(XeH ion) |
hl7:entryRelationship
|
|
0 … * |
R |
Specimen Collection Contains 2.16.840.1.113883.2.51.10.42 XeH Specimen Collection (DYNAMIC)
|
(XeH ion) |
hl7:entryRelationship
|
|
0 … * |
R |
Previous observations obtained for the same patient, test, same method, same unit
(1)
|
(XeH ion) |
where [@typeCode='REFR'] |
|
@typeCode
|
cs |
1 … 1 |
F |
REFR |
hl7:observation
|
|
1 … 1 |
R |
|
(XeH ion) |
@classCode
|
cs |
1 … 1 |
F |
OBS |
@moodCode
|
cs |
1 … 1 |
F |
EVN |
hl7:code
|
|
1 … 1 |
R |
|
(XeH ion) |
hl7:statusCode
|
|
1 … 1 |
R |
|
(XeH ion) |
@code
|
|
1 … 1 |
F |
completed |
hl7:effectiveTime
|
|
1 … 1 |
R |
|
(XeH ion) |
hl7:value
|
|
1 … 1 |
R |
|
(XeH ion) |
hl7:referenceRange
|
|
0 … 1 |
R |
Reference range for the current test result |
(XeH ion) |
@typeCode
|
cs |
0 … 1 |
F |
REFV |
hl7:observationRange
|
|
1 … 1 |
M |
|
(XeH ion) |
@classCode
|
cs |
0 … 1 |
F |
OBS |
@moodCode
|
cs |
0 … 1 |
F |
EVN.CRT |
hl7:value
|
|
0 … 1 |
|
interval (IVL) representation |
(XeH ion) |
hl7:interpretationCode
|
CE |
1 … 1 |
R |
|
(XeH ion) |
@code
|
CONF |
0 … 1 |
F |
N |
@codeSystem
|
0 … 1 |
F |
2.16.840.1.113883.5.83 (Observation Interpretation) |
lab:precondition
|
|
0 … * |
|
Extension to CDA Clinical statement |
(XeH ion) |
@typeCode
|
cs |
1 … 1 |
F |
PRCN |
lab:criterion
|
|
1 … 1 |
R |
|
(XeH ion) |
@classCode
|
cs |
1 … 1 |
F |
COND |
@moodCode
|
cs |
1 … 1 |
F |
EVN |
lab:code
|
CE |
1 … 1 |
R |
Code of the criterion (e.g. age, sex) |
(XeH ion) |
lab:value
|
|
1 … 1 |
R |
Value of the criterion |
(XeH ion) |